Programmable AC Power Source, 0-300V, 0-30A, Max 3000 VA, 45 Hz to 1200 Hz, 3-phase capability
The 9830 Series programmable AC power sources provide high performance and low total harmonic distortion in a 3U form factor. The addition of positive and negative DC offset voltages expands the AC capabilities to operate in DC and AC+DC output coupling modes. The user can select built-in and user-defined harmonic waveforms or select from standard sine, square or clipped sine outputs.
3-Phase power can be achieved by connecting 3 units of the same model in a master and slave configuration using the optional 3-Phase sync adapters. The frequency range is adjustable from 45 to 600 Hz in 3-phase mode.
Features & Benefits
- AC, DC and AC+DC power source
- Capability to setup 3-phase source using 3 units and the 3-phase kit (TL983P-KIT, see here)
- Low total harmonic distortion meets the IEC 61000-3-2 standard
- Comprehensive measurements Vrms, Arms, Vdc, +Apk, -Apk, inrush current, Hz, power factor, apparent power, reactive power, true power, and crest factor
- 0.98 power factor at AC input stage
- Built-in standard waveforms sine, square and clipped sine
- 30 built-in THD waveforms
- Amplifier mode with 1.2 kHz bandwidth for generating user-defined arbitrary waveforms
- Step, List and Pulse modes for generating power line disturbance (PLD) simulations
- List mode supports 10 user-defined programs with up to 100 programmable steps
- Generate custom harmonic waveforms on a PC and download them to the instrument′s 5 non-volatile memory locations
- Digital I/O port for external trigger, transient indication, failure status, remote inhibit, RS232, and analog output level programming interface
- Comprehensive protection modes OVP, OCP,OPP, OTP, fan failure, output timer and key lock
- Downloadable LabVIEW driver and soft panel software for remote control
- Standard USB (USBTMC-compliant), RS232, LAN, and GPIB remote interfaces
Applications
- Pre-compliance testing according to IEC61000-3-2 and IEC61000-4-11/14/28/34
- Simulate common grid faults, voltage dips and other disturbances
- Electromagnetic compatibility (EMC), according to IEC61000-3-2
- Evaluate transformers, TRIACs, SCRs, and passive components
Download Datasheet
YouTube Presentation Video