- 2-Fan Overhead Ioniser
Neutralizes electrostatic charges on insulators and ungrounded conductors in a 61 cm x 122 cm coverage area.
- Fast Decay Times (<3 seconds at 46 cm)
Discharges (removes) both positive and negative electrostatic charges within the coverage area.
- ±3 Volt Offset Voltage Balance
Meets required limits of ANSI/ESD S20.20 (<±35 volts), ANSI/ESD STM3.1 and ESD TR53.
- Dedicated High Voltage Power Modules with Balance Control at Each Fan
Allows each fan to be tuned to produce the optimum decay and balance in the coverage area.
- Sealed Plenum Air Flow
Prevents contamination from being introduced to workstation.
- Steady State DC Emitters
Spaced farther apart to prevent ion recombination, increase decay efficiency, and provide a broader coverage area of ionisation.
- Solid Tungsten Emitters
Maintains sharp point for optimal ioniser performance. Resists oxidation, melting and other damage that dulls the tip of the emitter
- 9 Speed Fan (61 to 94 L/s)
Consistent performance at all speeds. Low airflow may be used when working with small moving parts and components that may move with higher airflow.
- Shielded Bearings
Retains lubricant and minimizes contamination in the work area.
- Stainless Steel Housing
Minimizes foreign objects debris, corrosion, and other contaminations when used in clean or sensitive areas.
- NIST Calibrated with Certificate
Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. For more information on calibration of Desco Europe products, see Calibration.
- No power cord included
Choose from 200220 or 200225
- Made in the United States of America
Download Documentation TB-6534 - Overhead Zero Volt Ionizer
YouTube Presentation Video